Overview
With an SDM-CD16ACA, your Campbell Scientific data logger can automatically activate external ac or dc devices such as motors, pumps, heaters, valves, and fans. This ac/dc relay controller has 16 ports for connecting your ac or dc devices. Each port can be controlled automatically by the data logger’s program or controlled manually with an override toggle switch.
The SDM-CD16ACA is a RoHS-compliant version of the SDM-CD16AC.
Benefits and Features
- Allows the data logger to automatically turn devices on or off when a threshold (for example, temperature or water depth) has been reached
- Addresses up to 15 SDM-CD16ACAs, allowing up to 240 ports to be controlled by one data logger
- Includes LEDs that indicate when a port is active
- Provides a manual override for each port
- UL/CUL approved product; RoHS compliant
Detailed Description
The SDM-CD16ACA has a toggle switch that provides three positions: ON and OFF for manual override, and AUTO for data logger control.
- In the ON position, the common (COM) and normally open (NO) contacts are closed.
- In the OFF position, the normally open contact is open.
- In the AUTO position, the state of the relay is controlled by the SDM command issued through the data logger’s control ports or SDM terminal.
SDM Operation
The SDM-CD16ACA is a synchronously addressed data logger peripheral. Data logger control ports 1, 2, and 3 are used to address the SDM-CD16ACA, then clock out the desired state of each of the 16 control ports. Up to 15 SDM-CD16ACAs may be addressed, making it possible to control a maximum of 256 ports from the first three data logger control ports.
Specifications
Function | Allows a data logger to automatically activate external ac or dc devices such as motors, pumps, heaters, valves, and fans. |
Number of Channels | 16 |
Operating Temperature | -40° to +55°C |
Humidity | Non-condensing |
Contact Operation | Single pole double throw (break before make) |
Contact Material | Gold-clad silver |
Coil Voltage | 11 to 18 Vdc |
Coil Resistance | 360 Ω ±10% |
Expected Life (contact closures) | Mechanical 107 |
Actuation/Release Time | ~4 ms |
Toggle Switch |
|
Operating Voltage | 12 Vdc nominal (11 to 18 Vdc) |
Standards | Underwriters Laboratories (UL) listed product (E162021) |
Dimensions | 24.6 x 5.1 x 8.6 cm (9.7. x 2.0 x 3.4 in.) |
Weight | 0.8 kg (1.8 lb) |
Individual Contact Ratings |
|
Normally Open Rating |
|
Normally Closed Rating |
|
Current Drain @ 12 Vdc |
|
Quiescent | 6 mA |
Per Active LED | 45 mA (switch on or auto active) |
Compatibility
Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
Data Loggers
Product | Compatible | Note |
---|---|---|
21X (retired) | V | |
CR10 (retired) | V | |
CR1000 (retired) | V | |
CR1000X | V | |
CR10X (retired) | V | |
CR200X (retired) | X | |
CR206X (retired) | X | |
CR211X (retired) | X | |
CR216X (retired) | X | |
CR23X (retired) | V | |
CR295X (retired) | X | |
CR300 | X | |
CR3000 (retired) | V | |
CR310 | X | |
CR350 | X | |
CR500 (retired) | X | |
CR5000 (retired) | V | |
CR510 (retired) | X | |
CR6 | V | |
CR800 | V | |
CR850 | V | |
CR9000 (retired) | V | Although the CR9000 is compatible, the SDM-CD16ACA does not support its fastest communication rates and therefore is not practical for most of its applications. |
CR9000X (retired) | V | Although the CR9000X is compatible, the SDM-CD16ACA does not support its fastest communication rates and therefore is not practical for most of its applications. |
Mounting Equipment
Product | Compatible | Note |
---|---|---|
ENC10/12 | V | |
ENC10/12R | V | |
ENC12/14 | V | |
ENC14/16 | V | |
ENC16/18 | V | |
ENC24/30 | V | |
ENC24/30S | V |
Distributed Data Acquisition
Product | Compatible | Note |
---|---|---|
GRANITE 10 | V | |
GRANITE 6 | V | |
GRANITE 9 | V |
Additional Compatibility Information
Data Logger Considerations
Up to 15 SDMs can be connected to our data loggers. To communicate with connected SDM devices, the CR3000 and CR5000 use the SDM-C1, SDM-C2, and SDM-C3 ports. The other data loggers use ports labeled C1, C2, and C3. The 21X also requires channel 1H.
Programming
The SDMCD16AC Instruction controls SDM-CD16ACA operation in CRBasic. Edlog Instruction 29 controls SDM-CD16ACA operation in the CR7, and Edlog Instruction 104 controls SDM-CD16ACA operation in the CR10(X), CR23X, and 21X data loggers.
Power Considerations
The data logger’s rechargeable power supply, connected to our newer 1.2 A wall charger, is sufficient for powering the SDM-CD16ACA. The SDM-CD16ACA’s LEDs consume 45 mA each when active. If all 16 LEDs are active at once, a current drain of over 720 mA should be expected. If more than one SDM-CD16ACA will be used, a deep-discharge external battery may be necessary. This external battery should share a common grounding point with the data logger’s ground.
Campbell Scientific does not recommended using the data logger’s alkaline batteries to power the SDM-CD16ACA for long-term applications.
Enclosure Considerations
The SDM-CD16ACA requires a desiccated, non-condensing environment; a Campbell Scientific enclosure is recommended. Grommets and screws are provided to attach the flanges/bracket to the backplate of our enclosures.
For more detail, click here>>>